AH50

Description

Functional assay of the alternative complement pathway (AH50), measuring hemolytic activity dependent on intact alternative-pathway components.

Indications

Investigates suspected alternative complement-pathway deficiency/dysregulation, including atypical HUS, C3 glomerulopathy, and complement-inhibitor therapy monitoring.

Sample Type, Quantity & Conditions

Serum, Frozen

Special Precautions

Serum must be separated promptly and frozen; avoid room-temperature delay, which can consume complement and falsely lower functional activity. Do not use plasma.

Normal Range

30 - 113 %